June 7, 2026Journal of Clinical MedicineOpen Access

The median Vmax-AoDesc was 1.29 (IQR: 0.28) m/s, with an upper limit of 2.00 m/s, and age was the most important independent predictor (β = −0.392, p < 0.001).

View Full Paper
Ask AI
Bookmark
Share

Population

559 asymptomatic healthy athletes with an age of at least 12 years and a tricuspid aortic valve

Design

Cohort

Follow-up

median 3.0 (IQR: 2.1) years for a subset of 40 athletes

Authors

GCGeorgios A. ChristouDKDimitrios N. Kiortsis

Discussion

Loading...

Member takes

Overview

In healthy athletes, the upper limit of normal for maximum velocity of blood flow in the descending aorta is 2.00 m/s, with younger age being the strongest predictor of higher velocities.

Structured PICO

P
Population
559 asymptomatic healthy athletes with an age of at least 12 years and a tricuspid aortic valve (420 males, age: 29 ± 14 years)
O
Outcome
Normal range for the maximum velocity of blood flow in the descending aorta (Vmax-AoDesc) and its predictorssurrogate

In healthy athletes, the upper limit of normal for maximum velocity of blood flow in the descending aorta is 2.00 m/s, with younger age being the strongest predictor of higher velocities.

Cite This Study

Christou et al. (2026) studied this question.

synapsesocial.com/papers/6a250ce97def13d035e1d2b7https://doi.org/10.3390/jcm15114378