October 23, 2025TomographyOpen Access

Diagnostic Performance of CBCT in Detecting Different Types of Root Fractures with Various Intracanal Post Systems

View Full Paper
Ask AI
Bookmark
Share

Authors

SESerhat EfeoğluESEcem SiskoAÖAyşenur Öncü

Discussion

Loading...

Member takes

Overview

Analysis shows diagnostic accuracy in detecting root fractures in teeth, suggesting CBCT device choice affects outcomes.

Key Points

  • NewTom 7G demonstrated superior diagnostic accuracy for root fractures, particularly at smaller voxel sizes.
  • Observers showed almost perfect agreement with the gold standard in fracture detection, achieving κ ≥ 0.81.
  • Controlled fractures were induced using a universal testing machine, assessing multiple imaging modalities across two CBCT devices.
  • Selecting the right CBCT device and imaging parameters is crucial for accurate detection of vertical root fractures.

Cite This Study

Efeoğlu et al. (2025) studied this question.

synapsesocial.com/papers/68f9f86eb2c35e10cc4e3be1https://doi.org/10.3390/tomography11100116
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Comparison of imaging methods for detection of simulated horizontal and oblique root fractures in a new study model2025
  2. 2Research Progress of 3D Imaging Diagnosis of Tooth Fracture Based on CBCT2025
  3. 3Evaluation of the morphology of anterior permanent mandibular teeth in a population of adolescents from Kraków aged 18-20 years on the basis of pantomography and volumetric tomography (CBCT) - a comparative analysis.2024
  4. 4IMAGING TECHNIQUES IN ENDODONTIC DIAGNOSIS: A REVIEW OF LITERATURE2025
  5. 5Assessment of 3D Cone Beam Computed Tomography in Early Detection of Periapical Lesions: A Prospective Clinical Study2025