Blood Biomarkers of Fibrosis as Alternatives to FibroScan

View Full Paper
Ask AI
Bookmark
Share

Authors

AGAbhinav GuptaRDRanjana DuggalDGD. K. Gupta

Discussion

Loading...

Member takes

Overview

Cross-sectional analysis compares noninvasive methods for diagnosing liver fibrosis in MAFLD, indicating potential alternatives.

Key Points

  • FIB-4 score achieved the highest specificity (78%) and sensitivity (85%) among alternative methods compared to FibroScan®.
  • The area under the curve for FIB-4 was 0.82, closely aligning with the 0.88 of FibroScan®, suggesting it as a viable alternative.
  • FIB-5 and APRI showed moderate effectiveness with sensitivities of 80% and 76%, respectively, but lower specificity.
  • The AST/ALT ratio had poor diagnostic capability with 60% specificity and 65% sensitivity, making it less reliable.

Cite This Study

Gupta et al. (2025) studied this question.

synapsesocial.com/papers/68d4328c713b0b5dfea71f37https://doi.org/10.59556/japi.73.1114