September 10, 2025Atmospheric measurement techniquesOpen Access

Improving consistency in methane emission quantification from the natural gas distribution systems across measurement devices

View Full Paper
Ask AI
Bookmark
Share

Authors

JTJudith TettenbornDZDaniel Zavala‐AraizaDSDaan Stroeken

Discussion

Loading...

Member takes

Implication

Mobile measurements improve methane leak detection in gas distribution systems, highlighting the need for uniform emission quantification methods.

Key Points

  • Using the integrated spatial peak area improves consistency in methane emission estimates across measurement devices.
  • Controlled experiments in cities like London and Toronto evaluated various devices, revealing better results with the integrated spatial peak area metric.
  • A minimum of three transects and ideally five to seven is recommended for accurate emission quantification to aid in effective leak repair prioritization.
  • Variability was noted in measurements across the same release point, contributing to uncertainty in the emission quantification process.

Cite This Study

Tettenborn et al. (2025) studied this question.

synapsesocial.com/papers/68c23ed7b210217d64794255https://doi.org/10.5194/amt-18-3569-2025