September 5, 2025Clinics and PracticeOpen Access

Implantable Cardioverter–Defibrillator Therapies Following Generator Replacements—Long-Term Remote Monitoring Data

View Full Paper
Ask AI
Bookmark
Share

Authors

MDMaciej DyrbuśŁPŁukasz PykaAKAnna Kurek

Discussion

Loading...

Member takes

Overview

Analysis reveals arrhythmic risks and mortality rates in patients post ICD/CRT-D replacement, suggesting new stratification models are necessary.

Key Points

  • Among 134 patients monitored post-device replacement, 32.1% experienced appropriate ICD therapies and 38.0% reported all-cause mortality rates.
  • Findings indicate that predictors of mortality included appropriate antitachycardia pacing, reduced LVEF, and no history of myocardial infarction.
  • Kaplan–Meier estimates and Cox proportional hazards regression were employed to assess long-term outcomes and treatment predictors over a median follow-up of 3 years.
  • Improvement in LVEF was not shown to enhance survival or reduce device therapy interventions, calling for improved stratification models.

Cite This Study

Dyrbuś et al. (2025) studied this question.

synapsesocial.com/papers/68c239a3b210217d6477cebchttps://doi.org/10.3390/clinpract15090160
View Full Paper
Ask AI
Bookmark
Share

Also Consider

Synapse has enriched 5 closely related papers on similar clinical questions. Consider them for comparative context:

  1. 1Post-defibrillation survival: a measure of ICD and CRT-D effectiveness2026
  2. 2Dutch outcome in implantable cardioverter-defibrillator therapy extended follow up do it xl long term outcomes in a large primary prevention population2026
  3. 3Predictors of Atrial High‐Rate Episodes and Inappropriate Device Therapy in Implantable Cardioverter Defibrillators2025
  4. 4Identifying the vulnerable: navigating the predictors of implantable cardioverter defibrillator (ICD) therapy in the moderately reduced ejection fraction (EF) cohort2026 · 1 citations
  5. 5Survival of patients undergoing cardiac resynchronization therapy with or without defibrillator: the RESET-CRT project2022 · 52 citations